Support for an existing CMU building that is part of the chlorine system at the mill will be transferred to micropiles from existing spread footings to accommodate additional future heave. BAI designed the micropile elements including micropile structural and geotechnical capacity. Grout to ground bond strengths were developed in basalt rock beginning 30 feet below ground surface.